IEC 60601-2-1 Document Information:
Title
Medical electrical equipment – Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
Appareils électromédicaux – Partie 2-1: Exigences particulières de sécurité de base et de performances essentielles pour les accélérateurs d'électrons dans la gamme de 1 MeV à 50 MeV
International Electrotechnical Commission
Publication Date:
Oct 1, 2009
Scope:
Replacement:
This International Standard applies to the BASIC SAFETY and
ESSENTIAL PERFORMANCE of ELECTRON ACCELERATORS, hereafter referred
to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for
treatment of PATIENTS.
This particular standard, with the inclusion of TYPE TESTS and
SITE TESTS, applies respectively to the manufacture and some
installation aspects of ELECTRON ACCELERATORS
– intended for RADIOTHERAPY in human medical practice, including
those in which the selection and DISPLAY of operating parameters
can be controlled automatically by PROGRAMMABLE ELECTRONIC
SUBSYSTEMS (PESS),
– that, under NORMAL CONDITIONS and in NORMAL USE, deliver a
RADIATION BEAM of XRADIATION and/or ELECTRON RADIATION having
• NOMINAL ENERGY in the range 1 MeV to 50 MeV,-
• maximum ABSORBED DOSE RATES between 0,001 Gy × s–1
and 1 Gy × s–1 at 1 m from the RADIATION SOURCE,
• NORMAL TREATMENT DISTANCES (NTDs) between 0,5 m and 2 m from
the RADIATION SOURCE,
and
– intended to be
• for NORMAL USE, operated under the authority of appropriately
licensed or QUALIFIED PERSONS by OPERATORS having the required
skills for a particular medical application, for particular
specified clinical purposes, e.g. STATIONARY RADIOTHERAPY or MOVING
BEAM RADIOTHERAPY,
• maintained in accordance with the recommendations given in the
INSTRUCTIONS FOR USE,
• subject to regular quality assurance performance and
calibration checks by a QUALIFIED PERSON.
NOTE 1 In this particular standard, all references to
installation refer to installation in the RESPONSIBLE
ORGANIZATION'S premises.
NOTE 2 In this particular standard, all references to ABSORBED
DOSE refer to ABSORBED DOSE in water.
About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.