IEEE C62.92.4 Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part IV - Distribution


Purchase Information
Use this form to request purchase information on IEEE online subscriptions.
IEEE Collections
First Name:

Last Name:

Email address:

Document IEEE C62.92.4 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


IEEE C62.92.4 Document Information:

Title
Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part IV - Distribution

The Institute of Electrical and Electronics Engineers, Inc.

Publication Date:
Jan 1, 1991

Scope:

Foreword

This guide was prepared by the Working Group on the Neutral Grounding of Distribution Systems of the IEEE Surge- Protective Devices Committee. The guide deals with the neutral grounding of single- and three-phase ac utility primary distribution systems with nominal voltages of 2.4 kV through 34.5 kV. Not included are grounding of low-voltage secondary systems or consumer-owned facilities that are covered by other standards.

The neutral grounding of single- and three-phase ac electric utility primary distribution systems with nominal voltages in the range of 2.4–34.5 kV is addressed. Classes of distribution systems grounding are defined. Basic considerations in distribution system grounding—concerning economics, control of temporary overvoltages, control of ground-fault currents, and ground relaying—are addressed. Also considered are use of grounding transformers, grounding of high-voltage neutral of wye-delta distribution transformers, and interconnection of primary and secondary neutrals of distribution transformers.

Scope

This section of the guide is concerned with the neutral grounding of single- and three-phase alternating current (ac) electric utility primary distribution systems with nominal voltages in the range of 2.4 kV to 34.5 kV. For the purpose of this guide, the term “distribution” includes the substation providing power to distribution feeders, the distribution feeders, and the distribution transformers providing service at utilization voltages. The scope of this guide does not include the grounding of the low-voltage secondary systems supplied by distribution transformers, or consumer-owned facilities that are covered by other standards such as the National Electrical Code (NEC) [B6].

Keywords:

grounding
electric utilities
distribution systems
distribution system grounding
neutral grounding
primary distribution systems

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 