IEC 60287-1-2 Electric Cables - Calculation of the Current Rating - Part 1: Current Rating Equations (100% Load Factor) and Calculation of Losses - Section 2: Sheath Eddy Current Loss Factors for Two Circuits in Flat Formation


Purchase Information
Use this form to request purchase information on IEC online subscriptions.
IEC Collections
First Name:

Last Name:

Email address:

Document IEC 60287-1-2 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


IEC 60287-1-2 Document Information:

Title
Electric Cables - Calculation of the Current Rating - Part 1: Current Rating Equations (100% Load Factor) and Calculation of Losses - Section 2: Sheath Eddy Current Loss Factors for Two Circuits in Flat Formation

Câbles électriques - Calcul du courant admissible - Partie 1: Equations de l´intensité du courant admissible (facteur de charge 100 %) et calculs des pertes - Section 2: Facteurs de pertes par courants de Foucault dans les gaines dans le cas de deux circuits disposés en nappe

International Electrotechnical Commission

Publication Date:
Nov 1, 1993

Scope:

This section of IEC 287-1 provides a method for calculating the eddy current losses in the metallic sheaths of single-core cables arranged as a three-phase double circuit in flat formation. The sheaths are bonded at one point or are cross-bonded so that there are no significant sheath circulating currents. Where metallic sheaths are bonded at both ends there are significant circulating currents which result in a lower current-carrying capacity. A method of calculating circulating current losses for double circuits is under consideration.

The method provides coefficients which are applied as corrections to the loss factors for the sheaths of one isolated three-phase circuit. These corrections are negligible for cables where the parameter rn is less than about 0,1 ( m = ω/107 RS), which corresponds to a sheath longitudinal resistance higher than 314 μΩ/m at 50 Hz.

Consequently the method should be used for most sizes of aluminium-sheathed cables, but is not required for lead-sheathed cables unless they are unusually large:

The coefficients are provided in tabular form and have been computed from fundamental formulae for sheath losses, the evaluation of which calls for expertise in computer programming which might not be readily available in general commercial situations. The development of simplified formulae for some of the tabulated coefficients is under consideration.

Losses for cables in a single circuit will be covered in IEC 287-1 -1 (under consideration).

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 