IHS Inc., Home - http://www.ihs.com

IEC 60265-2 AMD 2 Amendment 2 High-Voltage Switches Part 2: High-Voltage Switches for Rated Voltages of 52 kV and Above


Purchase Information
Use this form to request purchase information on IEC online subscriptions.
IEC Collections
First Name:

Last Name:

Email address:

Document IEC 60265-2 AMD 2 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


IEC 60265-2 AMD 2 Document Information:

Title
Amendment 2 High-Voltage Switches Part 2: High-Voltage Switches for Rated Voltages of 52 kV and Above

Amendement 2 Interrupteurs A Haute Tension Deuxieme Partie: Interrupteurs A Haute Tension De Tension Assignee Egale Ou Superiure A 52 kV

International Electrotechnical Commission

Publication Date:
Aug 1, 1998

Scope:

This standard is applicable to three-phase alternating-current switches, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages 52 kV and above; and for rated frequencies up to and including 60 Hz. 

This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.

Notes 1. - Switches for gas insulated switchgear are covered by this standard.

2. - Switches having a disconnecting function and called switch-disconnectors are also covered by IEC Publication 129.

3. - Earthing switches are not covered by this standard. Earthing switches forming an integral part of a switch are covered by IEC Publication 129.

Object

The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application shall comply with the following service applications:

– carrying rated normal current continuously;

– carrying short-circuit currents for a specified time;

– switching of mainly active loads;

– switching of no-load transformers;

– switching of the charging current of unloaded cables, overhead lines or busbars;

– switching of closed-loop circuits;

– making short-circuit currents.

A further object of this standard is to establish requirements for limited-purpose and special-purpose switches used in transmission and distribution systems.

Limited-purpose switches shall comply with one or more of the service applications indicated above.

Special-purpose switches may comply with one or more of the service applications indicated above and, in addition, shall be suitable for one or more of the following applications:

– switching single capacitor banks;

– switching back-to-back capacitor banks;

– switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer;

– applications requiring an increased number of operating cycles;

– switching under earth fault conditions in systems with isolated neutral or in resonant earthed systems.

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 

Legal Statement | Site Map | Privacy Policy | Standards Store

Redirector