IHS Inc., Home - http://www.ihs.com

IEEE 484 Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications


Purchase Information
Use this form to request purchase information on IEEE online subscriptions.
IEEE Collections
First Name:

Last Name:

Email address:

Document IEEE 484 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


IEEE 484 Document Information:

Title
Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications

The Institute of Electrical and Electronics Engineers, Inc.

Publication Date:
Sep 12, 2002

Scope:

Stationary lead-acid batteries play an ever-increasing role in industry today by providing normal response and instrument power and backup energy for emergencies. This recommended practice fulfills the need within the industry to provide common or standard practices for the design of battery installations and the battery installation procedures. The methods described are applicable to installations and battery sizes using vented lead-acid batteries. The installations considered herein are designed for float operation with a battery charger serving to maintain the battery in a charged condition as well as to supply the normal dc load.

This recommended practice may be used separately, and when combined with IEEE Std 450™-1995, IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications, and IEEE Std 485™-1997, IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications, will provide the user with a general guide to sizing, designing, placing in service, maintaining, and testing a vented lead-acid battery installation. As a recommended practice, this document presents procedures and positions preferred by the IEEE.

This recommended practice provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries. Required safety practices are also included. This recommended practice is applicable to full float stationary applications where a battery charger normally maintains the battery fully charged and provides the direct current (dc) loads. However, specific applications, such as emergency lighting units, semiportable equipment, and alternate energy applications, may have other appropriate practices that are beyond the scope of this recommended practice.

The portions of this recommended practice that specifically relate to personnel safety are mandatory instructions and are designated by the word shall; all other portions are recommended practices and are designated by the word should.

Keywords:

instrumentation
resistance readings
installation design criteria
ventilation
receiving and storage
freshening charge
precautions
assembly
protective equipment
flooded cells
float operation
internal ohmic measurements
vented lead-acid batteries
alarms
testing
installation procedures
seismic
mounting
data collection

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 