IEC TR 60909-4 Short-Circuit Currents in Three-Phase a.c. Systems - Part 4: Examples for the Calculation of Short-Circuit Currents


Purchase Information
Use this form to request purchase information on IEC online subscriptions.
IEC Collections
First Name:

Last Name:

Email address:

Document IEC TR 60909-4 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


IEC TR 60909-4 Document Information:

Title
Short-Circuit Currents in Three-Phase a.c. Systems - Part 4: Examples for the Calculation of Short-Circuit Currents

Courants De Court-Circuit Dans Les Reseaux Triphases A Courant Alternatif - Partie 4: Exemples Pour Le Calcul Des Courants De Court-Circuit

International Electrotechnical Commission

Publication Date:
Jul 1, 2000

Scope:

Scope and object

This part of IEC 60909 is a technical report intended to give help for the application of IEC 60909-0 for the calculation of short-circuit currents in 50 Hz or 60 Hz three-phase a.c. systems.

This technical report does not include additional requirements but gives support for the modelling of electrical equipment in the positive-sequence, the negative-sequence and the zerosequence system (clause 2) and the practical execution of calculations in a low-voltage system (clause 3), a medium-voltage system with asynchronous motors (clause 4) and a power-station unit with its auxiliary network feeding a large number of medium-voltage asynchronous motors and low-voltage motor groups (clause 5).

The three examples given in clauses 3, 4 and 5 are similar to those given in IEC 60909 (1988) but they are revised in accordance with IEC 60909-0, which replaces it.

A subclause is added to the example in clause 3 to give a comparison between the results found with the application of the equivalent voltage source at the short-circuit location following the procedure given in IEC 60909-0 on the one hand, and results found with the superposition method on the other hand, taking into account different load-flow conditions before the short circuit.

Clause 6 of this technical report gives the circuit diagram and the data of a test network and the results for a calculation carried out in accordance with IEC 60909-0, to offer the possibility for a comparison between the results found with a digital program for the calculation of short-circuit currents and the given results for I“k, ip, Ib, Ik, I“k1 and ip1 in a high-voltage network with power-station units, generators, asynchronous motors and lines in four different voltage levels 380 kV, 110 kV, 30 kV and 10 kV.

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 

Legal Statement | Site Map | Privacy Policy | Standards Store

Redirector