NEMA C37.51 Document Information:

Title
For Switchgear - Metal-Enclosed Low-Voltage AC Power Circuit Breaker Switchgear Assemblies - Conformance Test Procedure

National Electrical Manufacturers Association

Publication Date:
Jan 1, 2003

Scope:

This Standard is a conformance testing standard optionally applicable to all metal-enclosed low-voltage ac power circuit breaker switchgear assemblies designed, tested, and manufactured in accordance with ANSI/IEEE C37.20.1-2002, Metal-Enclosed Low-Voltage AC Power Circuit Breaker Switchgear. This standard covers selected tests to demonstrate conformance of the basic switchgear section (which includes the structure, circuit breaker compartments, instrument compartments, buses, and internal connections) with Section 6, Tests, of ANSI/IEEE C37.20.1-2002. See ANSI/IEEE C37.20.1-2002 for assigned ratings and usual service conditions.

CONTROL AND INSTRUMENTATION COMPONENTS—PROTECTION REQUIREMENTS

LV switchgear assemblies usually include control and instrumentation components unique for the application that are not individually evaluated under this standard. However, these components, when utilized in circuits that obtain their energy from primary sources within the LV switchgear, must be suitably protected in accordance with 4.2.

NOTE—In this standard, the use of the term "LV switchgear" shall be considered to mean "metal-enclosed low-voltage alternating current power circuit breaker switchgear assemblies." The use of the term "circuit breaker" shall be considered to mean "low voltage alternating current power circuit breaker," unless qualified by other descriptive terms.

INSTALLATIONS NOT COVERED

This standard does not cover equipment intended for use in installations under the exclusive control of electric utilities for the purposes of communication or metering, or for generation, control, transformation, transmission, and distribution of electric energy located in buildings used exclusively by utilities for such purposes, or located outdoors on property owned or leased by the utility or on public highways, street, roads, and the like, or located outdoors by established rights on private property.

NOTE—An electric utility is an entity that is overseen by a public utility commission, a public service commission, or other regulatory agency having jurisdiction for such installations.

PURPOSE

This standard specifies the tests that shall be performed to demonstrate that the LV switchgear being tested conforms with the ratings assigned to it and meets the mechanical and electrical performance requirements specified in ANSI/IEEE C37.20.1-2002.

 

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 