EIA SP-4951 Surge Withstand Telecommunications Fuse Qualification Specification


Purchase Information
Use this form to request purchase information on EIA online subscriptions.
EIA Collections
First Name:

Last Name:

Email address:

Document EIA SP-4951 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


EIA SP-4951 Document Information:

Title
Surge Withstand Telecommunications Fuse Qualification Specification

Electronic Industries Alliance

Publication Date:
Jul 30, 2002

Scope:

Description

This specification defines the qualification program for surge withstand telecommunication fuses. Fuses covered will be limited to axial-leaded, radial-leaded and surface mount configurations having a current rating of no greater than 60 A, maximum voltage rating of 600 VAC/DC and interrupting rating of 10,000 A maximum. The qualification program is defined in table 1, and the flow diagram. Specification sheets can be added, as required, to define specific products or to cover unique / specific requirements. This document does not relieve the suppliers of their responsibility to maintain their own company’s internal qualification program and the fuses shall continue to meet all applicable requirements of UL 248-14 / CSA-C22.2 No. 248.14. Test procedures and requirements described in this specification have been generated for a Type II fuse, unless stated otherwise.

Three types of fuses are covered in this specification. They include:

Type I - The type I fuse is designed to operate (open) within a given time period at 200% overload. For a Type I fuse, the 200% overload shall be substituted throughout this specification where 250% overload is noted. All other requirements shall continue to be met.

Type II - The type II fuse is designed to operate (open) within a given time period at 250% overload. The remainder of this specification is written with the 250% overload test used as the standard.

Type III - The type III fuse is designed to operate (open) within a given time period at 300% overload. For a Type III fuse, the 300% overload shall be substituted throughout this specification where 250% overload is noted. All other requirements shall continue to be met.

Preconditioning

This process is intended to simulate exposure to the thermal and cleaning environments of the assembly process before qualification testing. The component assembly process simulation requirements for different types of processes are described in annex A.

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 