Title
Electrical Apparatus for Explosive Gas Atmospheres - Part 1-1: Flameproof Enclosures "d " - Method of Test for Ascertainment of Maximum Experimental Safe Gap

Materiel Electrique Pour Atmospheres Explosives Gazeuses - Partie 1-1: Enveloppe Antideflagrante "d" - Methode D´Essai Pour La Determination De L´Interstice Experimental Maximal De Securite

International Electrotechnical Commission

Publication Date:
Jul 1, 2002

Scope:

This part of IEC 60079 describes a test method intended for the measurement of the maximum experimental safe gaps for gas- or vapour-air mixtures under normal conditions of temperature1 and pressure so as to permit the selection of an appropriate group of flameproof enclosures.

The method does not take into account the possible effects of obstacles on the safe gaps2 .

1 An exception if made for substances with vapour pressures which are too low to permit mixtures of the required concentrations to be prepared at normal ambient temperatures. For these substances, a temperature 5 °C above that needed to give the necessary vapour pressure is used.

2 The design of the test apparatus for safe gap determination, other than that used for selecting the appropriate group of enclosure for a particular gas, may need to be different to the one described in this standard. For example, the volume of the enclosure, flange width, gas concentrations and the distance between the flanges and any external wall or obstruction may have to be varied. As the design depends on the particular investigation which is to be undertaken, it is unpracticable to recommend specific design requirements, but for most applications the general principles and precautions indicated in the clauses of this standard will still apply.

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 